Section AAttempt ail questions in brief. 2x 10=20
  • a
    Name the method of regulation known as optimistic method and why it is so called?
  • b
    What is the necessity of chording in the armature winding of alternator?
  • c
    What is the necd of parallel operation of two altemators?
  • d
    Define d-axis and q-axis synchronous reactance of the salient pole machine
  • e
    Name two types of induction motor based on rotor construction
  • f
    Calculate the slip for 2-pole, 50 Hz induction motor running at 2950 rpm
  • g
    Define crawling in an induction motor
  • h
    What are the advantages of skewing rotor bars in squirrel cage induction motor? i. Classify single phase induction motor j. Single phase induction motor is not self-starting. Give reason
Section BAttempt any one part of the following: 10x1=10
  • a
    Discuss the effects of armature reaction on the terminal voltage of alternator at (i) Zero pf lagging (ii) Zero pf leading and (iii) 0.8 pf lagging & (iv) Unity pf. Also, discuss synchronous impedance method for finding voltage regulation of
  • a
    cylindrical rotor machine. oe
  • b
    Explain in detail, hunting phenomenon in synchronous motor. Classify its causes and explain how they can be reduced —_ c.: Sketch and derive the Torque-Slip characteristics of a 3-phase induction motor indicating starting and maximum torque and the operating region. A 3-phase induction motor has a starting torque of 100% and maximum torque of 200% of full load torque. Determine slip at maximum torque and full load slip
  • d
    A 3-phase delta connected cage type induction motor when connected directly to 400 V, 50 Hz supply takes a starting’current of 100A in each stator phase calculate (i) The line current for DOL starting. (ii) Line and phase starting currents for star-delta starting. (iii) Line and phase currents for 70 % tapping on auto transformer starting. =...)
  • e
    Develop equivalent circuit diagram of single-phase induction motor based on double revolving field theory, ‘SECTION C
  • a
    Derive emf equation for an alternator. Also, develop expressions of pitch factor and distribution factor
  • b
    A 3-phase, 2-pole, 50 Hz, star-connected turboalternator has 54 slots with 4 conductors per slot. The pitch of the coil is 2 slots less than the pole pitch. Determine the useful flux per pole required to generate a line voltage of 3.3. https://www.aktuonline.com UY OA AA Subject Code: KEES03 PAPER ID-410606 ‘ Roll No
  • a
    Draw and explain the phasor diagram of a salient pole synchronous generator supplying full-load lagging current. Show that the power output per phase is . ErV, Ve xo-x,.. given by P= “sind faite 2@ where the notations have their usual meaning
  • b
    Explain how a synchronous motor operates as a synchronous condenser with the help of phasor diagram. A small industrial load of 500 kW at 0.6 pf lagging is supplied from a 3300 V. 3-phase, 50 Hz system. It is desired to raise the pf of the entire system to 0.8 lagging by means of a synchronous motor, which is also driving a pump so that the synchronous motor takes 100 kW from the lines. Determine the rating of synchronous motor
  • a
    Explain the (i) effect of varying of excitation of a synchronous generator connected to infinite busbar on the power factor, armature current and load angle and (ii) effect of load changes on a synchronous motor with the help of phasor diagrams
  • b
    Draw power flow diagram showing how electrical input is converted in to mechanical power output in an induction motor. A 4 pole, 400 V 3- phase, 50 Hz squirrel cage induction motor runs at speed of 1450 rpm at 0.85 pf lagging developing 11 kW power. The stator losses are 1100 W and mechanical losses are 400 W. Calculate (i) slip (ii) rotor copper loss (iii) rotor frequency (iv) line current (v) efficiency. https://www.aktuonline.com
  • a
    What is the necessity of starter in induction motor? With the help of neat diagram, discuss auto transformer and star-delta method of starting a squirrel cage induction motor. Also, discuss the limitations of these methods
  • b
    With the help of circuit diagram discuss speed control of induction motor by consequent pole method (ii) Rotor rheostat control and (iii) stator voltage control
  • a
    Write short notes on (i) Capacitor start motor (ii) Shaded pole motor and (iii) Repulsion motor
  • b
    A 220 V, phase induction motor give the following test results: Blocked rotor test : 120 V 9.6A 460W No load test :220V4.6A 125 W The stator winding resistance is 1.5 Q and during blocked rotor test, the starting winding is open. Determine equivalent circuit parameters https://www.aktuonline.com

Question text is extracted from the official AKTU question paper PDF above. Hindi translations are omitted — every question is printed in English in the original paper. Last verified: 2026-08-23.

Repeated Questions — KEE503

Questions that appeared in more than one session, found by comparing 3 years of Electrical Machines II papers (2021-22, 2022-23, 2023-24)

3x

Define crawling in an induction motor

Appeared in: 2021-22 · 2022-23 · 2023-24

3x

Derive emf equation for an alternator. Also, develop expressions of pitch factor and distribution factor

Appeared in: 2021-22 · 2022-23 · 2023-24

2x

What is the necd of parallel operation of two altemators?

Appeared in: 2021-22 · 2023-24

2x

Name two types of induction motor based on rotor construction

Appeared in: 2021-22 · 2022-23