Electrical Machines I (BEE402) - AKTU Question Paper 2023-24
B.Tech · Semester 4 · Free PDF Download
This is the official AKTU Electrical Machines I Previous Year Question Paper for B.Tech Semester 4, academic session 2023-24. Published by Dr. A.P.J. Abdul Kalam Technical University (AKTU/UPTU), Lucknow. Free PDF download — no login required.
Rate this paper
Questions Asked in 2023-24
Electrical Machines I (BEE402) — complete question paper · 70 marks · 3 Hours
- aExplain principle of electro-m echanical energy conversion with the help of block diagram
- bDefine energy and co-energy in a linear magnetic system
- cDescribe working of commutator in a DC machine as mechanical r ectifier
- dWrite the emf equation of D C Motor. Explain each term
- eDiscuss the need for starters in the operation of DC motors
- fDraw phasor diagram of ideal transformer at no load condition
- gList the conditions f or parallel operation of transformers
- aShow that the field energy in a linear magnetic system is given by
- bWith the help of neat sketch, explain armature reaction in DC machine
- cExplain in detail the speed control of DC motor by (i) Armatur e Control Method and (ii) Field Control Method
- dThe maximum efficiency of a 100 kVA, 1100/440 V, 50 Hz transfo rmer is 96%. This occurs at 75% of full load at 0.8 power factor lagging. Calculate the efficiency of transformer at half load and at 0.6 power factor lagging
- eDiscuss various types of connections employed in 3-phase trans formers
- aDerive an expression for Reluctance torque in rotating elec trical machines
- bFor a doubly excited linear ma gnetic system, derive an expr ession for the electromagnetic torque. 4 . A t t e m p t a n y one part of the following: 7 x 1 = 7
- aExplain the construction and working of DC machine with well-labelled diagram
- bDraw the internal and external characteristics of the DC sh unt generator. Also, explain (i) why the external characteristics turn backwards (ii) concept of vol tage build-up and critical field resistance in DC shunt generator. 5 . A t t e m p t a n y one part of the following: 7 x 1 = 7
- aExplain Swinburne’s test to calculate no-load losses in a DC machine. State its limitations over Hopkinson’s test
- bWith the help of neat diagram, explain the working of 3-poi nt starter. What are its limitations? How are these limitations overcome by 4-point starter? 6 . A t t e m p t a n y one part of the following: 7 x 1 = 7
- aA 200 kVA, 2000/440 V, 50 Hz, single phase transformer gave the following test results: O.C Test (hv) : 2 kV, 1.75 kW, 1.8 A S.C Test (lv) : 13 V, 1 kW, 300 A (i) Calculate the parameters of equivalent circuit as referred to H.V side (ii) Determine voltage regulation and efficiency at full-load, 0.8 power factor lagging
- bDraw and explain the complete equivalent circuit model of a practical transformer. Also, draw phasor diagram of practical transformer on-load condition at lagging power factor. 7 . A t t e m p t a n y one part of the following: 7 x 1 = 7
- aDescribe the 3-phase to 2-ph ase conversion in transformers with suitable diagram. Also, derive the expression for positioning of neural point
- bWhat is V-V connection? Show that the open delta connection has a kVA rating of 57.7% of the rating of the normal delta-delta connection
Question text is extracted from the official AKTU question paper PDF above. Hindi translations are omitted — every question is printed in English in the original paper. Last verified: 2026-08-23.
Repeated Questions — BEE402
Questions that appeared in more than one session, found by comparing 3 years of Electrical Machines I papers (2023-24, 2024-25, 2025-26)
List the conditions f or parallel operation of transformers
Appeared in: 2023-24 · 2024-25 · 2025-26
The maximum efficiency of a 100 kVA, 1100/440 V, 50 Hz transfo rmer is 96%. This occurs at 75% of full load at 0.8 power factor lagging. Calculate the efficiency of transformer at half load and at 0.6 power factor lagging
Appeared in: 2023-24 · 2024-25 · 2025-26
What is V-V connection? Show that the open delta connection has a kVA rating of 57.7% of the rating of the normal delta-delta connection
Appeared in: 2023-24 · 2024-25 · 2025-26
Draw phasor diagram of ideal transformer at no load condition
Appeared in: 2023-24 · 2025-26
Show that the field energy in a linear magnetic system is given by
Appeared in: 2023-24 · 2025-26
With the help of neat sketch, explain armature reaction in DC machine
Appeared in: 2023-24 · 2025-26
Explain Swinburne’s test to calculate no-load losses in a DC machine. State its limitations over Hopkinson’s test
Appeared in: 2023-24 · 2025-26
A 200 kVA, 2000/440 V, 50 Hz, single phase transformer gave the following test results: O.C Test (hv) : 2 kV, 1.75 kW, 1.8 A S.C Test (lv) : 13 V, 1 kW, 300 A (i) Calculate the parameters of equivalent circuit as referred to H.V side (ii) Determine voltage regulation and efficiency at full-load, 0.8 power factor lagging
Appeared in: 2023-24 · 2025-26
Describe the 3-phase to 2-ph ase conversion in transformers with suitable diagram. Also, derive the expression for positioning of neural point
Appeared in: 2023-24 · 2025-26